[DSA-AC] The line where two surface planes with different slopes meet....
Search Results "Floor Slope"
Commonly Searched Documents
-
GRADE BREAK
-
TRANSITION PLATE
[DSA-AC] A sloping pedestrian walking surface located at the end(s) of a gangway....
-
TRANSITION PLATE
[DSA-AC] A sloping pedestrian walking surface located at the end(s) of a gangway....
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet....
-
1127B.5, Item 4
A level landing 4 feet (1219 mm) deep shall be provided at the upper end of each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-810.2.3 Connection
boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
11B-306.3.1 General
Space under an element between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground shall be considered knee clearance and shall comply with Section 11B-306.3....
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
RAMP
A walking surface in an accessible space that has a running slope greater than 1:20....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
9.a [§ 4.7.5]
To answer this question you need to determine the slope of the flared sides to make sure it is 10 percent or less....
-
405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
Roll-in Access [1014.2.2]
To provide roll-in access into a camp shelter, a level or sloped entry route that complies with the technical requirements for an ORAR or trail, as applicable, must be provided along the...
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this document....
-
11B-405.7 Landings
Ramps that do not have level landings at changes in direction can create a compound slope that will not meet the requirements of this chapter....
-
GRADE BREAK
[DSA-AC] The line where two surface planes with different slopes meet....
-
TRANSITION PLATE
[DSA-AC] A sloping pedestrian walking surface located at the end(s) of a gangway....
-
Trailhead Signs
Length of the trail Type of surface on the trail Typical and minimum trail tread width Typical and maximum trail grade Typical and maximum trail cross slope...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....