The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
Search Results "Control End Wall"
-
11B-610.3.1 Rectangular seats
-
Section 36.204 Administrative Methods (Section-By-Section Analysis and Response to Comments)
or methods of administration that have the effect of discriminating on the basis of disability or that perpetuate the discrimination of others who are subject to common administrative control...
-
E2-1. Pedestrian Routes
[ADA Stds. 4.4] Note: These objects may be wall mounted or free standing....
-
Hallways
ADA Requirements Wall-mounted objects located between 27 inches and 80 inches above the floor may not protrude or stick out from the wall more than 4 inches....
-
704.3 Buildings on the same property and buildings containing courts
For the purposes of determining the required wall and opening protection and roof-covering requirements, buildings on the same property and court walls of buildings over one story in height...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 2
Reinforced walls for grab bars. ...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 1
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet...
-
1134A.7, Item 2
Reinforced walls for grab bars....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
- Just Manufacturing Enviro Series Sensor Single Hole Non-Mixing Backsplash Mount Gooseneck Faucet
- Just Manufacturing Enviro Series Sensor Single Hole Non-Mixing Deck Mount Gooseneck Faucet
- Just Manufacturing Enviro Series Deck Mount Sensor Lavatory Faucet
-
12 [§ 4.7.9]
12 [§ 4.7.9] When a curb ramp is located at a marked crossing, the area where the ramp run ends must be contained within the marked crossing....
-
4.20.3 Seat
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
-
4.20.3 SEAT
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
Illumination: ADA Standard Section 407.4.5
Section 407.4.5 covers the current ADA Standards for the illumination of the elevator car controls, platform, car threshold and car landing sill.
-
11B-407.4.5 Illumination
The level of illumination at the car controls, platform, car threshold and car landing sill shall be 5 foot candles (54 lux) minimum....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum....