Search Results "Door Maneuvering Clearance"
- NABCO GT1175-20 Slide by Slide RH ENTRY
-
NABCO GT1175-05R Single Slider RH - Pocketed 11-9-09
Requires the Premium User plan or above. (Login or upgrade your account!)
-
NABCO GT1175-09L Single Slider LH - Full Open Surface Mounted
Requires the Premium User plan or above. (Login or upgrade your account!)
-
NABCO GT 1175 All Glass Whisper Slider Full Open
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-809.10.5.1 Clear floor space
lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and knee and toe clearance...
- BEST Keypad EZ Door Hardware
- Norton Surface Mounted 2800ST Cam Action Closer
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture. The top of the fixture rim is a maximum...
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. The mammography machine is usable by both people...
-
§ 38.107(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
Clearances: ADA Standard Section 1002.4.4
Clearances for wheelchair spaces shall comply with 1002.4.4. EXCEPTIONS: 1. Where provided, securement devices shall be permitted to overlap required clearances. 2....
-
Check-Out Aisles and Sales and Service Counters
These commenters believed that the knee and toe clearance requirements will cause a reduction in the sales and inventory space at check-out aisles and other sales and service counters....
- Horton Automatics EasyAccess® Series 7100 for ADA Low Energy Applications
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
-
4.22.4 Water Closets
complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self-closing door...
- Cavity Sliders USA Inc. Pocket Insert Track
-
Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
Requires the Premium User plan or above. (Login or upgrade your account!)
- SDC EMLock® Magnetic Lock
-
Clearances: ADA Standard Section 403.5
Section 403.5 covers the current ADA Standards for clearances on walking surfaces that are part of an accessible route.
-
Registered Accessibility Specialist (RAS) Bulletin RAS 2014-04 Signs - Exit Doors
RAS 2014-04 Signs - Exit Doors Effective Date: July 7, 2014 2012 TAS Reference: 216.4.1 In accordance with TAS 216.4.1, doors at exit passageways, exit discharges, and exit...
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the...