Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
Search Results "Minimum Dimension"
-
1011.7 Outdoor Rinsing Showers
-
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns.
The minimum clear width of an accessible route shall be 36 in (915 mm) except at doors (see 4.13.5 and 4.13.6)....
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
§ 38.39(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
11B-802.1.2 Width
A single wheelchair space shall be 36 inches (914 mm) wide minimum. ...
-
Kitchens and Kitchenettes
Section 4.34.6 requires a clearance between opposing base cabinets, counters, appliances, or walls of at least 40 inches except in a U-shaped kitchen where the minimum clearance is 60 inches...
-
232 Detention Facilities and Correctional Facilities
title II rule provides scoping for newly constructed general holding cells and general housing cells requiring mobility features compliant with section 807.2 of the 2010 Standards in a minimum...
-
T304 Operable Parts
In the 2010 NPRM, the Access Board proposed to raise the minimum height of operable parts in non-rail vehicles from 15 inches to 24 inches. See 2010 NPRM, Section T805.2....
-
Back Support
In addition, clarification has been added that the dimensions for back support are measured from the surface of the seat. Comment....
-
Notes
Consequentially, health care professionals who are purchasing examination tables and chairs typically focus on the seated height dimension....
-
11B-706.5 Signal-to-noise ratio
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
703.2.1 Depth
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background....
-
5.4.2.1 Transfer Support Length for Stretchers
Transfer supports on stretchers should be a minimum of 15 inches long....
-
706.5 Signal-to-Noise Ratio
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum....
-
1133A.4, Item 2
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface....
-
4.33.2* Size of Wheelchair Locations
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.1.5 ACCESSIBLE BUILDINGS: ADDITIONS
Each addition to an existing building shall comply with 4.1.1 to 4.1.4 of 4.1, Minimum Requirements, except as follows:...
-
1011.8 Viewing Scopes
This section requires eyepieces on viewing scopes to be 43 inches minimum and 51 inches maximum above the ground....
-
4.33.2* SIZE OF WHEELCHAIR LOCATIONS
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
1133A.4, Item 2
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface....