ETA Interpretation/Opinion: Clearances between a handrail and wall surface: The 2010 ADA now requires the 1.5” as a minimum. 2012 NFPA 101 Life Safety Code will be requiring 2.25” minimum...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-503.5 Vertical clearance
and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2896 mm) minimum...
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-803.5 Coat hooks and shelves
Shelves shall be 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor or ground....
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches....
-
T402 Ramps and Bridgeplates
Section T402 has been slightly revised to clarify that the ramps and bridgeplate barriers must be a minimum height of 2 inches, but allows them to be reduced to less than 2 inches when they...
-
11B-405.5 Clear width
The clear width of a ramp run shall be 48 inches (1219 mm) minimum. Exceptions: 1. ...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Common Requirements (R304.5) (Section-by-Section Analysis) The clear width of curb ramp runs (excluding flared sides), blended transitions, and turning spaces must be 1.2 meters (4 feet) minimum...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
F224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
233.4.1
233.4.1 In sleeping rooms with more than 25 beds, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3....
-
6.7
6.7 Cinemark shall provide at least the minimum number of wheelchair spaces required in each auditorium as set forth in § 4.1.3(19)(a) of the ADA Standards....