Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
Search Results "Minimum Dimension"
-
604.7 Dispensers
-
Accessible Route Guidelines
They increase the minimum width for an accessible route from 36 inches to 48 inches....
-
5.7.1 Lift Compatibility Clearance in Base for M301
The base of the equipment shall provide a clearance 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination...
-
CONTENTS
CONTENTS Background Summary of the 19-inch recommendation Current Situation: The Vast Majority of Examination and Procedures Tables Are 32 Inches High Implication of a 19-Inch minimum...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2)....
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum....
-
11B-405.7.3.1
Bottom landings shall extend 72 inches (1829 mm) minimum in the direction of ramp run....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
1016.3 Clear Width
The clear width of outdoor recreation access routes shall be 36 inches (915 mm) minimum....
-
R407.6.3 Length
The landing clear length shall be 1.5 m (5.0 ft) long minimum....
-
T303.4 Clearance
Clearance between gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
T502.2.1 Over-the-Road Buses
For over-the-road buses, the vertical clearance at doorways shall be 65 inches (1650 mm) minimum....
-
4.13.11(1)
(1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....