Launch® for Universal Access A first in the industry, the EZ Launch® Accessible Transfer System for kayaks and canoes provides individuals with disabilities accessibility that exceeds the minimum...
Search Results "Minimum Dimension"
- EZ Dock EZ Launch® System for Kayaks and Canoes
- Allegion Falcon 2090 Cross Bar Exit Device
- Hoyer Advance-H Patient Lift
-
810 Transportation Facilities
The proposed rule specified that these dimensions were required to "the maximum extent allowed by legal or site constraints" (1002.2.2)....
- Door King Inc. 6004 Column Mount Swing Gate Operator
- Door King Inc. 6400 In-Ground Swing Gate Operator
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1011.7 Outdoor Rinsing Showers
Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
-
5.2.2 Transfer Surface Size Recommendations for M302
The transfer surface shall be 21 inches wide minimum and 15 inches deep minimum....
-
Website Access
For the visually impaired and others using screen readers the website should meet WCAG 2.0 minimum standards....
-
12186(d)(2) Vehicles and rail passenger cars
or rail passenger car be readily accessible to and usable by individuals with disabilities, if the design for such vehicle or car complies with the laws and regulations (including the Minimum...
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
12165(b) Rail passenger cars
this title that a rail passenger car be readily accessible to and usable by individuals with disabilities, if the design for such car complies with the laws and regulations (including the Minimum...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1011.7 Outdoor Rinsing Showers
Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
-
Error/Omission: Food service queuing areas are too narrow and do not provide adequate clear width for turns.
The minimum clear width of an accessible route shall be 36 in (915 mm) except at doors (see 4.13.5 and 4.13.6)....
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
§ 38.39(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...