Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
Search Results "Vertical Clearance"
Commonly Searched Documents
-
11B-504.5 Nosings
-
QUESTION: WHEN A RAIL OPERATOR CONSTRUCTS A NEW STATION PLATFORM OR ALTERS AN EXISTING STATION PLATFORM, DOES 49 CFR PART 37 REQUIRE THE RAIL OPERATOR ENSURE THAT THE PLATFORM IS AT LEAST 8 INCHES ABOVE TOP OF RAIL, EVEN IF THE RAILROAD OPERATOR WILL PROVIDE ACCESSIBILITY CONSISTENT WITH THE REQUIREMENTS OF SECTION 37.42?
., elderly persons) who might have difficulty ascending a vertical distance greater than the normal vertical gap between an 8-inch ATR platform and the first step of a railroad car....
-
233.1 General
Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels for accessible units....
-
2.2.3 Functional Reach
The five heights were normalized to the individual's vertical reach capabilities so that reaches were performed at, above and below shoulder height....
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
-
Jean Tessmer
Some of us prefer to mount to allow 28" knee clearance minimum to give the person in the wheelchair a lower shelf height of 32" depending on the thickness of your new #200 baby changer shelf...
- Proline Drain: Quick Drain USA - Side Waste Outlet Tub to Shower Conversion
- Corbin Russwin Inc. DC46900 Series Safeguard Door Closers
- Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
- Rockwood Manufacturing Company 110 x 70B Pull Plate 8" CTC Pull 3-1/2" x 15" Plate
- Rockwood Manufacturing Company 102 x 70B - Pull Plate 5-1/2" CTC Pull 3-1/2" x 15" Plate
- CRL Jackson 1200 Series Push Pad Door Exit Devices
- Lutron Sivoia QS Wireless Shading System
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Clear Floor Space [4.35.2]
Benches can overlap turning space where clearance (9 inches minimum) is available for toes....
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
- Populas Infinity Workstation
-
Section G: Ramps
(§§405.8, 505.4) G9 If the rise of the ramp is greater than 6" and the ramp or landing has a vertical drop-off on either side of the ramp,...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
206.3 Location
Additionally, accessible vertical interior circulation must be in the same area as stairs and escalators, not isolated in the back of the facility Note to Reader: The Department of...
-
Dispersion
This includes choice in both vertical and horizontal sections of a seating bowl and may vary by event....