Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
Search Results "Vertical Clearance"
Commonly Searched Documents
-
604.8.1.2 Doors
-
Facility
Knee and toe clearance complying with 306 shall be providing. (17” min. depth.) 902 Dining Surfaces and Work Surfaces. 902.3 Height....
-
L. Lavatory
Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl...
-
G. Chapter 6: Wheelchair Spaces and Securement Systems
The two areas in which the requirements in this chapter differ substantially from the proposed rule—wheelchair space maneuvering clearances and forward excursion barriers for rear-facing...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Where clear floor space at a lavatory is obstructed on both sides more than 2 feet, a clearance at least 36 inches wide is required....
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation
- Pilot Rock UT Series Side Accessible Picnic Table Using Recycled Plastic
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
-
Executive Summary
Key requirements apply to clear floor area, reach limits, knee and toe clearances and maneuvering clearances....
-
UDI
The starting clearance for each trial was the minimum clearance of the Canadian CSA B651-95 Standard....
-
2.0 Methodology
Knee Clearance Height (KCH), Knee Clearance Depth – Upper (KCDU), Knee Clearance Depth – Lower (KCDL) and Extended Depth (ED)....
-
11B-805.7 Built-in cabinets and work surfaces
Touch screen units shall be allowed to be vertically mounted with the centerline of the display screen no more than 52 inches above the floor in compliance with Section 11B-707.7.1.1....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Shower Threshold
However, the Board has revised the specification to allow thresholds at transfer compartments to be vertical or rounded instead of beveled....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
4. COMMON PATH OF TRAVEL ITEMS
Running slope of ramps, not to exceed 1:12 (8.33%) • Cross slope of walks and ramps not to exceed 1:48 (2.083%) • Landings and level area slopes not to exceed 1:48 (2.083%) • Vertical...
-
5.4.9 Interruptions along Transfer Support Gripping Recommendation for M301 and M302
Section 505.6 specifies that the gripping surface on the vertical support structure that is necessary for supporting the grip must not be discontinuous....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
4.34.3(2)(b) Reach Depth More Than 10 in
Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Character Height [4.30.3]
Recommendations: Both the horizontal and vertical viewing distance should be considered....
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
Location
Van-accessible parking spaces located in parking garages may be clustered on one floor (to accommodate the 98-inch minimum vertical height requirement)....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....