Search Results "Toilet Room Door"
Commonly Searched Documents
- S.51 All Aluminum Corner Detail
- Panda S.85/S.90 Sliding Systems Corner Detail
- TS.19 Thermally Broken Lift & Slide System Corner Detail
- TS.60 Bi- Fold Thermally Broken System Installation
- S.11 Wood Clad Lift & Slide Systerm Corner Detail
- TS.60 All Aluminum Thermally Broken Corner Detail
-
604.8.1.4 Toe Clearance
[ECTCR UFAS 4.17.4] Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
604.8.1.4 Toe Clearance
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance...
-
ETA Opinion: ADA Signage at Exit Doors
Different requirements apply to various types of signs: 1) Signs designating permanent rooms and spaces (e.g., men's and women's rooms, room numbers, exit signs [emphasis added]) must...
- Nana Wall Systems, Inc. Sliding Glass Walls HSW60 Video
-
805.1 General
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
805.1 General
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
Guidelines for Requirement 4
dwelling unit to include separate design specifications for: (a) single-story dwelling units, including single-story dwelling units with design features such as a loft or a sunken living room...
-
I. Public Toilet Rooms
Public Toilet Rooms: (1) In all public and common use toilet rooms throughout the Hotel and the Tower, Defendants will provide at least one lavatory with a counter-top that is 34 inches...
-
805.1 General
Medical care facility and long-term care facility patient or resident sleeping rooms required to provide mobility features shall comply with 805....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1011.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised...
-
F223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805....
-
223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805....
-
J. Bedside Clearance
________ ... is there clear passage at the foot of each bed that is at least 36" wide so that persons who use wheelchairs can approach and use the accessible features throughout the room...
-
Transient Lodging: ADA Standard Section 215.4
Section 215.4 covers scoping requirements in the current ADA Standards for fire alarm systems in transient lodging.
-
4.35.4 Bench
Every accessible dressing room shall have a 24 in by 48 in (610 mm by 1220 mm) bench fixed to the wall along the longer dimension....
-
Guidelines for Requirement 3
(usable doors) as required by §100.20(c)(2)....
-
F206.7.6 Guest Rooms and Residential Dwelling Units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...