1.1.3.2, Item 3
-
Pool Stairs: ADA Standard Section 1009.6.1
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
Size: ADA Standard Section 1009.5.6
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
M301.2.1, M302.2.1 Transfer Height
M301.2.1, M302.2.1 Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum...
-
Element-by-Element Safe Harbor for Existing Facilities
For example: The 1991 Standards allowed light switches, thermostats, and other controls to be installed at a maximum height of 54 inches....
-
4.1.4 OCCUPANCY CLASSIFICATIONS
Buildings and facilities shall comply with these standards to the extent noted in this section for various occupancy classifications, unless otherwise modified by a special application section...
-
§ 38.171(b)
(b) If portions of the vehicle or conveyance are modified in a way that affects or could affect accessibility, each such portion shall comply, to the extent practicable, with the applicable...
- Pilot Rock PQT3-4 Square Pedestal Table Using Recycled Plastic
- Pilot Rock PQT3-4 Square Pedestal Table Using Lumber
-
References
Technical Report (AMRL-TR−74‒102) (AD A025 240). Aerospace Medical Research Laboratory, Wright-Patterson Air Force Base, OH....
-
7. What remedies address violations of the ADA’s integration mandate in the context of disability employment systems?
Various indicators of integration are relevant to Olmstead employment remedies, such as individuals with disabilities’ interaction with non-disabled persons to the fullest extent possible...
-
Guarantees of accessible guest room reservations. (Section-by-Section Analysis)
a public accommodation that owns, operates, leases (or leases to) a place of lodging shall guarantee accessible guest rooms that are reserved through a reservations service to the same extent...
-
[A] ALTERATION
[DSA-AC] A change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility....
-
13. Do the provisions for openings in floor and ground surfaces in Section 302.3 apply to walking surfaces in play areas?
This applies to elevated platforms and decks on composite play structures where ramp access is provided on the structure....
-
Q. What are the limitations on the obligation to make a reasonable accommodation?
These factors include the nature and cost of the accommodation in relation to the size, resources, nature, and structure of the employer's operation....