Check-Out Aisles and Sales and Service Counters
-
11B-802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1219 mm) deep minimum....
-
11B-802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1219 mm) deep minimum....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
Width: ADA Standard Section 802.1.2
A single wheelchair space shall be 36 inches (915 mm) wide minimum Where two adjacent wheelchair spaces are provided, each wheelchair space shall be 33 inches (840 mm) wide minimum....
-
Clear Floor Space [4.20.2]
Clear Floor Space [4.20.2] Clear floor space at tubs, which is dimensioned according to the approach, may overlap required turning space within the room....
-
Inpro Corporation JointMaster® 103 VCT Expansion Joint Systems Floor to Floor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation JointMaster® 101 Floor Expansion Joint Covers Floor to Wall
Requires the Premium User plan or above. (Login or upgrade your account!)
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, a turning space complying with ABAAS section 304.3 shall be provided....
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, as applicable, a turning space complying with ABAAS section 304.3 shall be provided....
-
11B-607.6 Shower spray unit and water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. [2010 ADAS] Advisory 607.6 Shower Spray Unit and Water. ...
-
11B-607.6 Shower spray unit and water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 11B-607.6 Shower spray unit and water....
-
1018.2 Aisles in assembly spaces
Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1029....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
11B-608.6 Shower spray unit and water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
F225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory F225.2 Storage....
-
225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory 225.2 Storage....
-
606.5 Exposed Pipes and Surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....