Door Protection Plate 204S 0.125" gauge with 4-sided bevel Material: - Clear Plastic...
Search Results "Pull Side"
Commonly Searched Documents
- Hager Companies Door Protection Plate 204S
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
1014.2.1.1 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Built-up Curb Ramps [4.7.6]
Recommendation: Curb ramps with returned sides or concave flares are preferred over built-up curb ramps with convex flares because they provide greater edge protection....
-
Diagonal Curb Ramps [4.7.10]
In addition, a segment of straight curb at least 2 feet long must be provided on each side of the curb ramp and within the marked crossing....
-
1014.2.1.1 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
Clear Floor Space [§309.2]
If clear floor space is obstructed on both sides more than half the minimum required depth, a wider clearance (36” min.) is required for maneuvering and sway....
-
Thresholds [§404.2.5]
A maximum height of 3/4” is permitted for existing or altered thresholds if they have a beveled edge on each side with a slope not steeper than 1:2....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
Reach Ranges (Advisory)
Recommended forward or side reach ranges are: 20 to 36 inches for 3 to 4 year-olds 18 to 40 inches for 5 to 8 year-olds 16 to 44 inches for 9 to 12 year-olds...
-
A4.2.1(3) Space Requirements for Passing
Able-bodied persons in winter clothing, walking straight ahead with arms swinging, need 32 in (815 mm) of width, which includes 2 in (50 mm) on either side for sway, and another 1 in (25...
-
A4.2.1(3) Space Requirements for Passing
Able-bodied people in winter clothing, walking straight ahead with arms swinging, need 32 in (815 mm) of width, which includes 2 in (50 mm) on either side for sway, and another 1 in (25...
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
Measuring Techniques
Zone 3 specifies that the inertia reel be unlocked and the shoulders and torso permitted to move forward and to the sides as necessary for maximum reaches....
-
1022.9 Stairway identification signs
11A, Section 1143A or Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side...