The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT...
Search Results "Pull Side"
Commonly Searched Documents
-
11B-610.3.1 Rectangular seats
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
610.3.1 Rectangular Seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. Figure 610.3.1 Rectangular Shower Seat...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
802.1.3 Depth
Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
-
Is color contrast required for stair nosings?
The ASME A17.1 code requires escalator steps to be demarcated by yellow lines 2” wide maximum along the back and sides....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
5. Q: Recently a job applicant for a police officer's job came into the police department with fingers that were visibly impaired. The police department required that he demonstrate that he could pull the trigger on the police issue firearm and reload it before a conditional job offer was made. Did this violate the ADA?
A: No. If an individual has a "known" disability that would reasonably appear to interfere with or prevent performance of job functions, that person may be asked to demonstrate how...
-
1. Question: What is the minimum width needed for a non-level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
varies from one builder to another, but it is not uncommon for the passenger car edge of the lift platform in the fully deployed position to be a number of inches away from the actual side...
-
Accessible Entrance
exist at an entrance, access can be achieved in a variety of ways -- for example, by using an alternate accessible entrance, adding a short ramp, modifying the area in front or to the side...
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
Cross slopes—the side-to-side slope of an outdoor recreation access route—must not exceed 1:33 (3 percent), as shown by figure 37....
-
4.1.3(17)(a)
Unless otherwise specified, accessible telephones may be either forward or side reach telephones. 2 A bank consists of two or more adjacent public telephones, often installed as a unit...
-
Accessible Round Table Style
Side aisles require at least six feet between the table and the side wall or other obstructions....
-
Segway Human Transporter
Its footprint is not much larger than the human body's and has a handlebar and platform similar to a scooter, but with two wheels side by side....
-
610.3.1 Rectangular Seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. Figure 610.3.1 Rectangular Shower Seat...
-
1 [§ 4.7.3]
If the curb ramp has flared sides, which can also be seen in the illustration to the right [below], do not include them in the measurement....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...