., Segway®), or any mobility aid designed to operate in areas without defined pedestrian routes." ...
Search Results "Pedestrian Elements"
-
"Other Power-Driven Mobility Device" (Section-by-Section Analysis)
-
11B-705.1.2.2.2.1 One entrance/exit point
shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and the turning space shall provide a minimum 36 inches (914 mm) wide portion without detectable warnings to allow pedestrian...
-
11B-705.1.2.2.2.1 One entrance/exit point
shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and the turning space shall provide a minimum 36 inches (914 mm) wide portion without detectable warnings to allow pedestrian...
-
Getting to the Water—Beach Access Routes
Beach access routes allow pedestrians to get across the beach so they can play, swim, or participate in other beachrelated [sic] activities....
- SmartCells Flooring: Anti-Fatigue Matting
-
1016.9 Protruding Objects
Constructed elements on outdoor recreation access routes, passing spaces, and resting intervals shall comply with 307. Advisory 1016.9 Protruding Objects. ...
-
Taking Photographs
It is always useful to first take a photo that will clearly identify the site, then the elements surveyed....
-
3.4.8 Viewing Areas Accessed by Vehicular Ways
The outdoor recreation access route shall connect the distinct viewing locations, accessible outdoor constructed elements, and other accessible elements, accessible spaces, and accessible...
-
1016.9 Protruding Objects
Constructed elements on outdoor recreation access routes, passing spaces, and resting intervals shall comply with 307. Advisory 1016.9 Protruding Objects....
-
R402.2 Protrusion Limits
Objects with leading edges more than 685 mm (2.25 ft) and not more than 2m (6.7 ft) above the finish surface shall protrude 100 mm (4 in) maximum horizontally into pedestrian circulation...
-
Need for Rulemaking
Act that establish the need for accessibility guidelines, the Access Board’s current accessibility guidelines, and why the Access Board is proposing to issue accessibility guidelines for pedestrian...
-
11B-101.2 Reserved
Elements in the 2010 Standards not eligible for the element-by-element safe harbor are identified as follows – (A) Residential facilities dwelling units, sections 233 and 809....
-
101.2 Effect on Removal of Barriers in Existing Facilities
Elements in the 2010 Standards not eligible for the element-by-element safe harbor are identified as follows–– (A) Residential facilities dwelling units, sections 233 and 809....
-
11B-101.2 Reserved
Elements in the 2010 Standards not eligible for the element-by-element safe harbor are identified as follows – A. Residential facilities dwelling units, sections 233 and 809. B. ...
-
11B-101.2 Reserved.
ii) The safe harbor provided in §35.150(b)(2)(i) does not apply to those elements in existing facilities that are subject to supplemental requirements (i.e., elements for which there are...
-
11B-203.9 Employee workstations
Spaces and elements within employee workstations shall only be required to comply with Sections 11B-207.1, 11B-215.3, 11B-302, 11B-303, 11B-308.1.1, 11B-308.1.2, and 11B-404.2.3, unless...
-
11B-203.9 Employee workstations
Spaces and elements within employee workstations shall only be required to comply with Sections 11B-207.1, 11B-215.3, 11B-302, 11B-303, 11B-308.1.1, 11B-308.1.2, and 11B-404.2.3, unless...
-
C2‒3
Are all objects that hang over the pedestrian routes at least 80 inches above the route?...
-
Clear Width [4.8.3]
Recommendation: It is often advisable that ramps be wider than the minimum required where usage of the ramp may be subject to appreciable pedestrian traffic....
-
§ 38.71(b)(2)
(2) Vehicles designed for, and operated on, pedestrian malls, city streets, or other areas where level boarding is not practicable shall provide wayside or car-borne lifts, mini-high platforms...
-
SIDEWALK
A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK....
-
SIDEWALK
A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK....
-
R406.3 Unobstructed Side Reach
Where a clear space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380...
-
11B-411.2.1.3.4 Position
The face of individual elements or group of individual elements that are operated by user input shall slope away from the user at 15 to 25 degrees from the vertical plane. ...