Where counters or teller windows have security glazing to separate personnel from the public, a method to facilitate voice communication shall be provided. Telephone handset devices,...
Search Results "Hybrid Surface System"
-
11B-904.6 Security glazing
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
M302.2.3 Size
Transfer surfaces shall be 21 inches (610 mm) wide minimum and 17 inches (430 mm) deep minimum....
-
Step 3: Apply the Accessibility Provisions
This step involves looking at FSTAG, sections 7.4.1 through 7.4.8, which contain the technical requirements for trail grade, cross slope, resting interval, surface, clear tread width, passing...
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers....
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
F219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table F219.3....
-
219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
6.8.2 Grade and cross slope
Where the surface is paved or is elevated above the natural ground, the surface shall not be steeper than 1:48 (2 percent) in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
-
1011.2.3 Slope
The slope of the clear ground space surface shall not be steeper than 1:48 in any direction....
- inLOOP Personal Loop Digital 600
-
219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
2.1.3 Receivers
2.1.3 Receivers The major advantage of IL systems is that they permit listeners whose hearing aids incorporate telecoils to use their own hearing aids as the receiver....
-
Sec. 12142. Public entities operating fixed route systems. [Section 222]
[See subsections ...]
-
Problem Three
Problem Three: Accessible parking spaces or access aisles are on a sloped surface and do not provide a level area for a safe transition from the voter’s car to a wheelchair....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground....
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....