Reservation Systems Requirements for Places of Lodging
-
11B-306.3.3 Minimum required depth
At dining and work surfaces required to be accessible by Section 11B-226.1, knee clearance shall extend 19 inches (483 mm) deep minimum at 27 inches (686 mm) above the finish floor or ground...
-
11B-306.3.3 Minimum required depth
At dining and work surfaces required to be accessible, knee clearance shall extend 19 inches (483 mm) deep minimum at 27 inches (686 mm) above the finish floor or ground....
-
11B-306.3.3 Minimum required depth
At dining and work surfaces required to be accessible by Section 11B-226.1, knee clearance shall extend 19 inches (483 mm) deep minimum at 27 inches (686 mm) above the finish floor or ground...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
Gangway Slope and Rise Exceptions
For example, where the vertical distance between where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level is 4 feet, the gangway...
-
1018.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
3.1.3.1 Slope of Vehicle Parking Areas
When the surface is not paved, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
1018.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
6.7.2 Cross Slope
Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48 (2 percent). ...
-
II. Research Methodology
Research Methodology The research design for this study of playground surfaces has been in development since 2005 with input from a national advisory committee. ...
- Mobi-Mat® Recpath™ ADA Beach Access Mat
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301) The Committee recommends a transfer surface size on imaging equipment be a minimum of 28 inches long by a minimum...
-
Conclusions
of the expert review of the literature highlight the need for future studies particularly as it relates to how environmental factors such as height and gap distances, use of handholds, surface...
- Williams Sound FM ADA KIT 1 - Large-Area Value Kit
-
4.7.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
902.2 Clear Floor or Ground Space
902.2 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided.
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided.
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided.
-
4.1.3(18)
(18) If fixed or built-in seating or tables (including, but not limited to, study carrels and student laboratory stations), are provided in accessible public or common use areas, at...
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided.