Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate...
Search Results "Sink Height"
-
1133A.6 Kitchen sink faucet controls
-
1133A.6 Kitchen sink faucet controls
Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate...
-
3.3.5 Seat Height
Comparisons of research findings on the seat heights for power chairs and scooters showed that mean seat heights measured in the UDI study were comparable to seat heights for the power chairs...
-
Seat Height [4.16.3]
Seat Height [4.16.3] Height preferences vary among people with disabilities....
-
4.16.3* Height
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
4.16.3* HEIGHT
The height of water closets shall be 17 in to 19 in (430 mm to 485 mm), measured to the top of the toilet seat (see Fig. 29(b))....
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
Counter Surface Height
Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
-
11B-306.2.3 Minimum required depth
Exceptions: The toe clearance shall extend 19 inches (483 mm) minimum under sinks required to be accessible by Section 11B-212.3....
-
11B-306.2.3 Minimum required depth
Exceptions: The toe clearance shall extend 19 inches (483 mm) minimum under sinks required to be accessible by Section 11B-212.3....
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter āIā....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use....
-
4.34.6 KITCHENS
Accessible or adaptable kitchens and their components shall be on an accessible route and shall comply with the requirements of 4.34.6.
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5....
-
1133A.4, Item 1
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for the kitchen sink installation....
-
1133A.4, Item 1
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for the kitchen sink installation....
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-