The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
Search Results "Sink Height"
Commonly Searched Documents
-
11B-903.5 Height
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
Seat Height
Commenters noted that this specification should be clarified as applying to the height as measured at the top of the seat surface. Response....
-
Faucets: ADA Standard Section 606.4
Section 606.4 covers the current ADA Standards for the faucet controls of lavatories and sinks.
-
11B-606.4 Faucets
Controls for faucets shall comply with Section 11B-309. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
Pool Stairs: ADA Standard Section 1009.6.1
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
Pressalit Care Lift for Manually Height Adjustable Worktop
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Highest and Lowest Heights Obtained
For all of the minimum height transfers, the 75th and 95th percentiles were at the minimum transfer height possible with the station (10 inches)....
-
4.1.3 Adjustable Height Chairs with and without Footplates
4.1.3 Adjustable Height Chairs with and without Footplates Patients seated in adjustable height examination chairs typically rest their feet on the floor or on a footplate or have their...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1012.2 Height
occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, both as applicable in Section 101.2, guards whose top rail also serves as a handrail shall have a height...
-
Transfer Heights
For instance, level seat heights were 21.7± 1.2 inches and 22.1±1.4 inches for the first and second phases respectively....
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. [2010 ADA Standards] 212.1 General....
- Just Manufacturing Backsplash Mounted Sink Faucet with Gooseneck Spout
-
R410.7 Height from Finish Surface
R410.7 Height from Finish Surface. Visual characters shall be 1.0 m (3.25 ft) minimum above the finish surface....
-
Utility Sinks
A utility sink is deeper than a standard restroom basin or kitchen sink and can be used to clean large pots or equipment....
-
R410.6 Character Height
R410.6 Character Height. Minimum character height shall comply with Table R410.2.5....
- Just Manufacturing Backsplash Mounted Sink Faucet with Soapdish and Tube Spout
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...
-
11B-212.1 General
Where provided, kitchens, kitchenettes, wet bars and sinks shall comply with Section 11B-212. ...