A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
Search Results "Serving Space"
Commonly Searched Documents
-
1134A.6, Item 1.2
-
§ 35.151(g)(2)
(2) Assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards and have seating encircling, in whole or in...
- Access Board: Single User Toilet Room Size and Layout
-
11B-502.7 Relationship to accessible routes
Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes....
-
III-7.5180 Assembly areas
This section specifies the number of wheelchair seating spaces and types and numbers of assistive listening systems required in assembly areas. 1) Wheelchair seating: Requirements for...
- TotTurf® Synthetic Grass: Play Spaces
-
1134A.6, Item 1.2
A water closet may project a maximum of 12 inches (305 mm) into the opening provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
- citEcar Electric Vehicles - ADA Enclosed Passenger Shuttle Wheelchair Ramp
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space....
-
F206.2.2 Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
206.2.2 Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
11B-812.10.4 Location
EV chargers shall be adjacent to, and within the projected width of, the vehicle space being served. Exceptions: 1....
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3....
-
12162(a)(2)(B)(ii)
(ii) have space to park and secure a wheelchair;...
-
R304.5.3 Cross Slope
The cross slope of curb ramps, blended transitions, and turning spaces shall be 2 percent maximum....
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable....
-
Fraudulent purchase of designated accessible seating. (Section-by-Section Analysis)
The Department has received numerous comments regarding fraudulent attempts to purchase wheelchair spaces for patrons other than those who use wheelchairs. ...
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
206.2.2 Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....