Sections 35.150 and 35.151 specifically address the obligations of public entities to ensure accessibility by providing curb ramps at pedestrian walkways....
Search Results "Curb Ramp Top Landing"
-
‘‘Facility.’’
-
Facility (Section-by-Section Analysis)
Sections 35.150 and 35.151 specifically address the obligations of public entities to ensure accessibility by providing curb ramps at pedestrian walkways....
-
Parking Spaces [4.6.3]
For this reason, built-up curb ramps cannot project into access aisles....
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
-
12. Annual Commitment for Program Access Improvements
ramps leading into crosswalks; (k) Elimination of curb ramp lips on curb ramps; (l) Installation of accessible tree grates, or other compliant remediation, where such grates are missing...
-
Alterations to Existing Facilities
For example, if an alteration project involves only installing pedestrian signals at existing intersections and there are no detectable warning surfaces on the curb ramps at the intersections...
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
1010.1.6 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
Small Entities Affected by Rule
The final rule affects small entities that construct or alter camping facilities, picnic facilities, viewing areas, trails, and beach facilities on federal lands pursuant to a concession...
-
308 Reach Ranges
Gas pumps are often located on curbs at least 6 inches high for safety reasons....
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways and ramps, exit passageways, exterior exit stairways and ramps and horizontal exits....
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways and ramps, exit passageways, exterior exit stairways and ramps and horizontal exits....
-
Suggested accessibility guidelines for exterior concrete surfaces
Suggested accessibility guidelines for exterior concrete surfaces Current standards for ramps, sidewalks, and intersections and other concrete tolerances are given in ACI 117, Specification...
-
504 Stairways
This section requires that landings subject to wet conditions be designed to prevent the accumulation of water (504.7)....
- Inclusion Solutions Blue Parking Stop
-
Dune Crossings [1018.10]
Edge protection in the form of a curb or barrier must prevent the passage of a 2-inch sphere where any portion of the sphere is within 2 inches of the dune crossing surface....
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...