Figure 18: APS and curb ramps that were not installed as designed. Figure 19: Another view of the same corner....
Search Results "Designated Aisle Seat (Assembly)"
-
Issue 14: Inspection of contractor’s work - Beware of field changes!
-
§ 38.125(d)(1) Requirements
All intercity rail cars required to be accessible by §§38.111 (a) and (e) of this subpart shall provide at least one, but not more than two, mobility aid seating location(s) complying with...
-
M303.2.1 Orientation (Section-by-Section Analysis)
The MDE NPRM proposed to require wheelchair spaces to be designed so that a patient in a wheelchair using diagnostic equipment would be oriented in the same direction that other non-wheelchair...
-
A. Passenger Drop-Off Areas
Access aisle depth is at least 5 feet. 2. Access aisle length is at least 20 feet. 3. [sic] 3....
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve....
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car designation...
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car designation...
-
X. Designated Agencies
The following agencies are designated for enforcement of title II for components of State and local governments that exercise responsibilities, regulate, or administer services, programs...
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car designation...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
Kohler Veil™ One-Piece Elongated Dual-Flush Wall-Hung Toilet With Reveal® Quiet-Close™ Seat
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stages.
Under the current 1991 Standards, a compliant accessible route connecting seating locations to performing areas is permitted to go outside the assembly area and make use of an indirect interior...