., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
Search Results "Counter Height"
Commonly Searched Documents
-
1132A.4, Item 4
-
302.2 Carpet
Pile height shall be ½ inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
Tread Obstacles [1017.5]
The limit on the height of tread obstacles on trails, passing spaces, and resting intervals is based on the surface material used....
-
1003.2.12.2 Opening limitations
Open guards shall have balusters or ornamental patterns such that a 4-inch-diameter (102 mm) sphere cannot pass through any opening up to a height of 34 inches (864 mm)....
-
302.2 Carpet
Pile height shall be ½ inch (13 mm) maximum. Exposed edges of carpet shall be fastened to floor surfaces and shall have trim on the entire length of the exposed edge....
-
1134A.7, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
4.34.3(2)(b) Reach Depth More Than 10 in
vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion of the automated teller machine or surround is more than 10 in (255 mm), the maximum height...
-
1134A.7, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
1011.3 Operable Parts
This section requires operable parts of outdoor constructed features to comply with the technical requirements for the height of operable parts in 309.3 of the Architectural Barriers Act...
-
903 Benches
Specifications for benches address clear floor or ground space (903.2), size (903.3), back support (903.4), height (903.5), structural strength (903.6), and slip resistance in wet locations...
-
III. Proposed alternative mechanisms to enhance patient access to diagnostic imaging equipment
For example, in a CT/PET system, the patient support surface is located on top of a transporter, which adds to the height of the transport surface....
-
1. Abdomen depth (AD)
., knee clearance height, foot clearance height or depth). Table 1 and Figure 1 show the percentiles and maximum observed values for male and female wheelchair users....
-
1134A.7 Water closets
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....
-
Comments
., Amtrak and a commuter railroad) and that, in many cases, the floor heights of the various railroads' equipment are different....
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
11B-504.8 Floor identification
11B-703.3 and 11B-703.5 shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in height...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
Technical Memorandum TM 2013-22 Storage (Kitchens and Kitchenettes)
Counter surfaces shall not be considered shelf space nor used to satisfy the requirements of 804.5....
-
A. Changes in Level
.: back of registration counter, housekeeping storage rooms, kitchens, administrative offices, etc.) Yes __ No __ N/A __ Comments: ___________________________________________...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
11B-306.3.3 Minimum required depth
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...