In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
Search Results "Non-Elevator Building"
-
4.10.13* CAR POSITION INDICATORS
-
§ 36.404 Alterations: Elevator exemption.
[See subsections ...]
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
10.1 General
Every station, bus stop, bus stop pad, terminal, building or other transportation facility, shall comply with the applicable provisions of 4.1 through 4.35, sections 5 through 9, and the...
-
REFERENCES
REFERENCES: California Code of Regulations (CCR) Title 24 Part 2, California Building Code, Sections 11B-202.4 This Interpretation of Regulations (IR) is intended for use by the...
-
Requirement 6. Reinforced walls for grab bars.
Section 100.205(c)(3)(iii) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
4.10.5 RAISED CHARACTERS ON HOISTWAY ENTRANCES
All elevator hoistway entrances shall have raised floor designations provided on both jambs. The centerline of the characters shall be 60 in (1525 mm) from the floor....
-
Can back doors and freight elevators be used to satisfy the program accessibility requirement?
Only as a last resort and only if such an arrangement provides accessibility comparable to that provided to people without disabilities, who generally use front doors and passenger elevators...
-
1008.2.3 Water Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
1008.2.3 Water Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
1008.2.3 Water Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Advisory 1008.2.3 Water Play Components....
-
T504 Passenger Access Routes
[See subsections ...]
-
CHAPTER 5: DOORWAYS, CIRCULATION PATHS AND FARE COLLECTION DEVICES
[See subsections ...]
-
CHAPTER 4: BOARDING AND ALIGHTING
[See subsections ...]
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
4.10.5 Raised and Braille Characters on Hoistway Entrances
All elevator hoistway entrances shall have raised and Braille floor designations provided on both jambs. The centerline of the characters shall be 60 in (1525 mm) above finish floor....
- GameTime Apollo Playground Equipment
-
1009.1 Accessible means of egress required
In addition to the requirements of this chapter, means of egress, which provide access to, or egress from, buildings for persons with disabilities, shall also comply with the requirements...
-
1009.1 Accessible means of egress required
In addition to the requirements of this chapter, means of egress, which provide access to, or egress from, buildings for persons with disabilities, shall also comply with the requirements...
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
11B-1008.2.3 Water play components
Transfer systems complying with Section 11B-1008.3 shall be permitted to connect elevated play components in water. Advisory 11B-1008.2.3 Water play components....
-
4.1.6(1)(k)(i)
(i) These guidelines do not require the installation of an elevator in an altered facility that is less than three stories or has less than 3,000 square feet per story unless the building...