In alterations, smaller car sizes (minimum 47 inch width and 69 inch length) are permitted in cases of technical infeasibility, including where limited by existing shaft configurations (...
Search Results "Continuous Width"
-
Floor Plan of Elevator Cars [4.10.9]
-
Shape and Diameter
A gripping surface width between 1¼ to 1½ inches diameter is specified....
-
Rough Form and Foundation Inspection
slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear floor spaces are correctly installed so proper slopes, cross slopes, widths...
-
4.34.6.7* OVENS
For side-opening ovens, the door latch side shall be next to the open counter space, and there shall be a pull-out shelf under the oven extending the full width of the oven and pulling out...
-
1.1.12 Ramp cross slope
slope of ramps by establishing elevations at the extreme edges of the ramp at the top and bottom of the ramp and calculate the cross slope at these two locations using the horizontal ramp width...
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-704.2.1.2 Forward approach
If an additional 6 inches (152 mm) in width of clear floor space is provided, creating a clear floor space of 36 inches by 48 inches (914 mm by 1219 mm), the enclosure may extend more than...
-
Serving Counters
A minimum width of 36 inches should be provided with a 42 inch width preferred, if readily achievable....
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
All X-ray tables meet the 28-inch table width....
-
A) Accessible Parking
If the accessible route is located in front of the space, install wheelstops or other barriers to keep vehicles from reducing width below 36 inches....
-
How Broken Overhead Channels Guarantee Subterranean Flooding
The Rapid Accumulation of Subterranean Moisture Even if the sheer, crushing hydrostatic pressure does not immediately cause massive, visible structural cracking, the continuous presence...
-
FIRST CAUSE OF ACTION
Plaintiffs are informed, believe, and thereon allege that Defendant and its agents and employees have violated and continue to violate Title II of the ADA by failing to timely respond to...
- Don-Jo Mfg., Inc. Vertical Rod Protector 85
- Don-Jo Mfg., Inc. Vertical Rod Protector 81
-
Q15: Does the Amendments Act require the Department to revise or create new Section 504 regulations to implement the Amendments Act?
OCR continues to assess whether additional guidance or further publications are needed. 16 For example, OCR interprets the Section 504 regulatory language defining "is regarded as having...
-
14.4 Q. If a covered multifamily dwelling has a below grade common use parking garage, is there a requirement for a vertical clearance to allow vans to park?
This issue was addressed in the preamble to the Guidelines, but continues to be a frequently asked question....
-
D. Executive Order 13609: Promoting International Regulatory Cooperation
This cooperation began with the 2005 EU-US Economic Initiative (http://trade.ec.europa.eu/doclib/docs/2006/june/tradoc_127643.pdf) and continued through the work of the Access Board with...
-
Additional Technical Criteria Considered for Handrails on Ramps
These technical criteria are available at http://www.access-board.gov/ada-aba/final.cfm#a505 and address continuity, height, clearance, gripping surface, cross section, surfaces, fittings...
-
II. ACTIONS TO BE TAKEN BY PALACE SPORTS AND ENTERTAINMENT, LLC:
For actions that have no specific deadline, PSE shall commence them as soon as practicable but no later than October 1, 2013, and shall continue for as long as PSE or its successor in interest...
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1....
-
382.9 What may foreign carriers do if they believe a provision of a foreign nation’s law prohibits compliance with a provision of this Part?
If we are late, then the foreign carrier may continue to carry out the policy or practice involved until we do respond, and if the request is denied the Department would not take any enforcement...
- GE® 27" Drop-In Electric Range JM250DFBB