level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with technical requirements for running slope, cross slope, clear width...
Search Results "Character Width (VMS)"
Commonly Searched Documents
-
M303.3.3 Ramped (Section-by-Section Analysis)
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
recommendation A transfer support (for transfer surfaces less than or equal to 24” deep) is to extend horizontally along the side of the patient scanning/imaging table at least the minimum width...
-
Boating facilities. (Section-by-Section Analysis)
In existing boarding piers, the required clear pier space may be perpendicular to and extend the width of the boat slip if the facility has at least one accessible boat slip, providing that...
-
Design Criteria for the Transfer Station
The station was designed to investigate the impact handhelds, back rests, heights, and seat widths have on transfer performance....
-
Boating facilities. (Section-by-Section Analysis)
In existing boarding piers, the required clear pier space may be perpendicular to and extend the width of the boat slip if the facility has at least one accessible boat slip, providing that...
-
R306.3.1 Separation
European and Australian roundabouts provide a 610 mm (24 inch) width of tactile surface treatment from the centerline of the curb ramp or blended transition across the full width of the...
-
4.9.4 HANDRAILS
Figure 19 Stair Handrails (2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of...
-
Station 2-Three-Point Turn
Designers can use this information to select shared use path widths and, if necessary, build wider turnaround areas, so that users can execute U-turns within the confines of the path....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
Sec.36.304(d)(2)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
M305.2.3 Height
EXCEPTION: Where the width of the transfer surface for imaging beds exceed 24 inches (610 mm), the tops of the gripping surfaces shall be permitted to be 3 inches (75 mm) minimum and 6 inches...
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the outdoor recreation access route....
-
Court Sports
Accessible routes must comply with all ADAAG requirements, such as width and changes in level or surface, and must directly connect both sides of the court....
-
704.8.2 First story
The unoccupied space shall be on the same lot or dedicated for public use, shall not be less than 30 feet (9144 mm) in width, and shall have access from a street by a posted fire lane in...
-
407.3.3 Numeric Keys
Some keypads will have a double width zero key and decimal key instead of the asterisk and pound signs found on a telephone keypad. These examples conform to this provision....
-
Clear Floor Space [4.19.3]
Additional width is required where the clear floor space is obstructed on both sides more than 2 feet (see page 17)....
-
1016.6 Openings
Where possible, drainage grates should be located outside the minimum clear width of the outdoor recreation access route....
-
1015.3 Viewing Space
The viewing space is required to be 32 inches maximum and 51 inches minimum high above the ground and extend the full width of the clear ground space....
-
Built-Up Curb Ramps
Otherwise, consider a wider ramp width (48” min.) so that maneuvering does not occur near drop-offs. ...
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
- Hoyer Advance-E Power Lift