11B-502 Parking Spaces 11B-503 Passenger Drop-Off and Loading Zones 11B-504 Stairways 11B-505 Handrails...
Search Results "Handrail Clearance"
Commonly Searched Documents
-
DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
-
Landings [4.8.4]
Handrail extensions can wrap around landings. It is recommended that landings of exterior ramps be drained so that water does not accumulate on the surface....
-
11B-405.9 Edge protection
Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with Section 11B-406.2.2. 2....
-
11B-405.9 Edge protection
Exceptions: Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with Section 11B-406.2.2....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
4.31.9(2)
The shelf shall be capable of accommodating a text telephone and shall have 6 in (152 mm) minimum vertical clearance in the area where the text telephone is to be placed....
-
4.10.9 Floor Plan of Elevator Cars
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1‒1/4 in (32 mm)....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The clearance between the car platform sill and the edge of any hoistway landing shall be no greater than 1-1/4 in (32 mm)....
-
Clear Floor or Ground Space and Turning Space
Clearances are required at accessible elements, fixtures, and controls so that people with disabilities, including those who use wheelchairs, can approach and use them....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
- Pilot Rock WXT and WXTH Picnic Table Using Aluminum
- Pilot Rock WUT and WUTH Picnic Table - Using Aluminum
- Bobrick ConturaSeries Surface-Mounted Seat-Cover Dispenser B-4221
- Bobrick Recessed Paper Towel Dispenser B-318
-
Table of Contents
Positions CHAPTER 3: BUILDING BLOCKS 301 General 302 Floor or Ground Surfaces 303 Changes in Level 304 Turning Space 305 Clear Floor or Ground Space 306 Knee and Toe Clearance...
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
4.2.6* SIDE REACH
If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig. 6(c). Figure 6 Side Reach...
-
Clear Floor Space [§309.2]
Clear Floor Space Additional clearance is required if the space is obstructed on three sides for more than half the depth to allow easier maneuvering into the space....
- Murdock Manufacturing Grab Bars
- Adaptive Access
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...