Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
Search Results "Handrail Clearance"
-
Conclusions
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Recessed Lavatories
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
T207.4.2. Large vehicles
EXCEPTION: Where high-back seats are provided, handrails located overhead or on overhead luggage racks shall be permitted instead of stanchions or handholds....
-
Temporary Solutions for Election Day
Suggestion: Install a portable ramp with edge protection and handrails as shown in the figure or relocate the accessible voting to another area that is on an accessible route....
-
Wading Pools
The sloped entries for wading pools are not required to have handrails....
-
Lavatories Adjacent to Partitions
Per 11B-606.2, we know that a clear space positioned for a forward approach is required (with exceptions), with proper knee and toe clearance. ...
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
504 Stairways
Section 504 covers stairways, including treads, risers, nosings, and handrails....
-
R407.9.1 Extended Ramp Surface
The surface of the ramp run or landing shall extend 305 mm (1.0 ft) minimum beyond the inside face of a handrail complying with R409. Advisory R407.9.1 Extended Ramp Surface....
- Handi-Ramp Galvanized Steel Ramps
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided....
-
1018.10 Dune Crossings
Where the slope of a beach access route at a dune crossing is steeper than 1:20 (5%), handrails complying with 505 and curbs or barriers shall be provided....
-
Fur out the wall
Just need to make sure all other clearances, (42" from center line to adjacent wall/fixture is clear, etc.) ...