Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
Search Results "Transfer Surface Height"
-
2.5.4 Slope
-
Section F: Voting Area
_______________________ Location name:______________________ F Within the Voting Area Yes No N/A Comments/Remedies F1 Are floor surfaces...
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
Guest Rooms
Bed heights for accessible rooms should be between 17-23 inches above the floor Do not have border frame which prevents the wheelchair from being directly next to the mattress....
-
Cross Slope (R302.6) (Section-by-Section Analysis)
In exterior environments, a maximum cross slope of 2 percent is generally accepted as adequate to allow water to drain off paved walking surfaces....
-
1015.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
F226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902....
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...
- Landscape Forms GO Outdoor Table
-
2. What does the ADA require for accessibility of pools?
One means of entry/exit must be a fixed pool lift or sloped entry; the other entry can be a transfer wall, transfer system, or pool stairs....
- SuperDeck Beach Boardwalk
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
-
4.1.2(17)
(17) If fixed or built-in seating, tables, or work surfaces are provided in accessible spaces, at least 5 percent, but always at least one, of seating spaces, tables, or work surfaces shall...
-
Pemko 193 Slip resistance
Hello ETA, I see that you can ask for slip resistance by adding a coating to the Pemko 193 plate. Any experience with this application? Is this a permanent slip resistance or...
-
Accessible Fishing Piers and Platforms
Sections 237 and 1005 of the 2010 Standards require at least twenty-five percent (25%) of railings, guards, or handrails (if provided) to be at a 34-inch maximum height (so that a person...
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
11B-405.3 Cross slope
Cross slope is the slope of the surface perpendicular to the direction of travel....
-
§ 38.113(d)(4) Exception
Retrofitted vehicles shall be coordinated with the platform in existing stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B-608.5.1 Reserved
[2010 ADAS] 608.5.1 Transfer Type Shower Compartments....
-
Light Rail Platform Slope
The Board has explicitly specified that rail platforms shall slope no more than 1:48 in any direction, consistent with cross slope provisions for walking surfaces in section 403....
-
Check-Out Aisles [7.3]
Operable controls, including card swipes, must be with maximum reach heights (54 inches for a side reach, 48 inches for a forward reach)....
-
4.16.2 Clear Floor Space
However, in accommodating assisted transfers, these guidelines were less of an issue than providing space adjacent to the water closet for caregivers and including a 5’ turning radius in...