Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
Search Results "Toilet Compartment"
Commonly Searched Documents
-
603.2.3 Door Swing
-
604.5 Grab Bars
Grab bars shall not be required to be installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement...
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
Exception 3
Altering one existing toilet facility. Altering existing elevators. Altering existing steps. Altering existing handrails....
-
Revolving Doors or Turnstiles
While automated revolving doors, if large enough, may be usable by people with disabilities, certain questions remain about the appropriate maximum speed, minimum diameter, compartment size...
-
H. Men's Spa and Fitness Center Locker Room
(2) Defendants will convert the accessible shower compartment in the Men's Spa Dressing Room and Men's Fitness Center Locker room to a compliant shower including compliant controls,...
-
Access to Health Care for People with Disabilities
Ethics Matters: A publication of the Donnelley Family Disability Ethics Program Access to Health Care for People with Disabilities © Rehabilitation Institute of Chicago 2009....
-
1134A.3 Powder rooms
When the powder room is the only toilet facility located on an accessible level, it shall comply with the Option 2 Items listed above, plus all additional requirements located in Sections...
-
1134A.3 Powder rooms
When the powder room is the only toilet facility located on an accessible level, it shall comply with the Option 2 Items listed above, plus all additional requirements located in Sections...
-
11B-604.5.1 Side wall
FIGURE 11B-604.5.1 ‡‡ SIDE WALL GRAB BAR AT WATER CLOSETS ETA Editor's Note At Hospital toilets and bathrooms used by patients, the 2013 California Electrical Code (2013 CEC)...
-
Advice for Passengers with Service Animals
If you have a very large service animal or multiple animals that might need to be transported in the cargo compartment, contact the airline well in advance of your travel date....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The 2010 Standards provide a gap of 3 inches between the edge of a shower seat and the shower compartment entry, and the gap does not appear to interfere with transferring onto and off the...
- Bobrick ClassicSeries Recessed Seat-Cover Dispenser B-301
-
11B-805.4 Examination, diagnostic and treatment rooms
Toilet rooms that are accessed from an examination, diagnostic or treatment room shall also be accessible. ...
-
604.5 Grab Bars
Grab bars shall not be required to be installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement...
-
604.5 Grab Bars
Grab bars shall not be required to be installed in a toilet room for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement...
-
A4.16.4 Grab Bars
Some wheelchair users can transfer from the front of the toilet while others use a 90-degree approach....
-
A4.16.4 GRAB BARS
Some wheelchair users can transfer from the front of the toilet, while others use a 90-degree approach....
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
- American Standard Madera 1.28 gpf EverClean Toilet with Exposed Manual Flush Valve System Top View
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System Plan View
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System Front View
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System Plan View
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System Front View