Where two or more outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one outlet shall not be required to comply with 309....
Search Results "Counter Slope"
Commonly Searched Documents
-
11B-205.1 General
-
Guidelines for Requirement 5
Other commenters asked whether light switches and electrical outlets in the inside corners of kitchen counter areas, and floor outlets are permissible. Response....
-
Clear Floor or Ground Space
ground space is also sometimes called "wheelchair parking space." 30-inch (760 mm) by 48-inch (1220 mm) minimum area May overlap accessible routes and maneuvering spaces Slope...
-
A. The Substantive Legal Dispute
numerous deficiencies, including: (1) unsafe, non-compliant, or missing ramps; (2) broken pedestrian rights of way that are cracked, crumbled, steep, sunken, or uneven or that have improper slopes...
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
Parking
Accessible parking spaces (including access aisles) must be level (maximum slope 1:48 in all directions) and each access aisle must adjoin an accessible route. ...
-
Scoping [4.1.2(1), 4.1.3(1)] and Location [4.3.2]
Clear width, surface texture, running and cross slope, and the treatment of changes in level help determine the usability of walking surfaces by people with mobility impairments....
-
Purpose of the project
For instance, when this project began, tolerances for the measurement of the slope, flatness, and smoothness of exterior walking and rolling surfaces in concrete, asphalt, unit masonry,...
-
11B-505.6 Gripping surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
- Behavioral Safety Products #SF370 Ligature Resistant Sensor Faucet
- AquaTrek2 ADA Step System
-
11B-809.8 Doors
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25 mm), provided a ramp with a maximum slope of 1:8 is permanently installed as illustrated...
-
Accessible Routes (Exterior and Interior)
The route must be free of abrupt changes in level, steps, high thresholds, or steeply sloped walkways....
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
1. Accessible route(s)
On-grade walks or paths between separate buildings with covered multifamily dwellings, while not required, should be accessible unless the slope of finish grade exceeds 8.33% at any point...
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
11B-505.6 Gripping surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
Maintenance (Trail Terminology)
and removing rock slides Maintaining trail tread, such as filling ruts, reshaping a trail bed, repairing a trail surface or washouts, installing riprap to retain cut and fill slopes...
-
Sight Lines
A variety of factors determine the quality of "vertical" sight lines, such as the distance from performance areas, row spacing, staggering of seats, and floor slope....
-
Gurney Accessible Bathroom
Slip-resistant tile (.6 CFR wet and dry) with multiple grout lines for traction Floor tile installed at a 2% slope for drainage Flexible threshold for easy use from a wheelchair...
-
11B-406.6 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
11B-805 Medical care and long-term care facilities
high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter...
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
-
3. New Construction vs. Alterations
curb ramps installed must meet the accessibility requirements of the ADA to the maximum extent feasible.10 Scoping requirements in the ADA Standards establish limitations for the running slope...