Published in the Federal Register on January 9, 2017. 36 CFR Part 1195 RIN 3014-AA40 Standards for Accessible Medical Diagnostic Equipment AGENCY: Architectural and...
Search Results "Platform Height"
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
-
Exceptions When Conditions Do Not Permit Full Compliance
the conditions as shown in the Table 2 under the Executive Summary, and permits exceptions based on the conditions to any provision in the technical requirements for tent pads and tent platforms...
-
HOW TO MEASURE TRANSFER HEIGHTS IS IMPORTANT
HOW TO MEASURE TRANSFER HEIGHTS IS IMPORTANT Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
COSTS TO LOWER MINIMUM TABLE HEIGHT
COSTS TO LOWER MINIMUM TABLE HEIGHT To be useful for its intended purpose, examination tables and chairs must maintain a high height of at least 32 inches, so that the health care provider...
-
3.3.6 Knee Clearance Height, minimum
3.3.6 Knee Clearance Height, minimum Knee clearance heights for the four sets of standards range from 650 mm (25.6 in.) (Australia) to 700 mm (27.6 in.) (U.K.) (Figure 3‒6)....
-
Water Flow Height
The minimum 4 inch height is intended to allow use of cups for persons who may need to use them....
-
Accessible Sports Facilities - A Summary of Accessibility Guidelines for Recreation Facilities
United States Access Board Accessible Sports Facilities: A Summary of Accessibility Guidelines for Recreation Facilities This information has been developed and reviewed in...
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
2. Analysis of footrest clearance height and depth
Analysis of footrest clearance height and depth Any base support or flange for the mammography machine at floor level (inside the clear floor space width) would obstruct some wheelchair...
-
Conditions for Exceptions [1019]
Technical Requirements Specific Provisions Applies To Outdoor constructed features Clear ground space Alterations only Tent pads and tent platforms...
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
M305.2.8 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to require that transfer supports not rotate in their fittings (proposed M305.2.3). Five commenters addressed this provision. Four of the commenters disagreed...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer supports shall not rotate when locked in place for patient...
-
III. CONCLUSION
For the foregoing reasons, neither Section 904.4.1 nor its exception requires clear counter space at sales and service counters subject to the ADA’s requirements.
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.
-
1136A.2 Switch and control heights