11B-604.9.2 Clearance. Clearance around a water closet shall comply with Section 11B-604.3.
Search Results "Ground Floor Exit"
-
11B-604.9.2 Clearance
-
§ 38.113(d) Coordination with boarding platforms
(d) Coordination with boarding platforms—
-
§ 38.73(d) Coordination with boarding platform
(d) Coordination with boarding platform—
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
604.9.2 Clearance
Clearance around a water closet shall comply with 604.3.
-
604.9.2 Clearance
604.9.2 Clearance. Clearance around a water closet shall comply with 604.3.
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4]
Recommendations: Capitalization should be used for the first letter of proper nouns and names but not for "restroom" or "exit."...
-
e-v
Are raised letters and Braille characters used to identify each floor button and each control? [ADA Standards § 4.10.12] Yes No...
-
Regulatory Impact Analysis.
rooms with in-swinging doors; stairs; elevators; location of accessible routes to stages; accessible attorney areas and witness stands; assistive listening systems; and accessible teeing grounds...
-
11B-216.2 Designations
Examples include interior signs labeling restrooms, room and floor numbers or letters, and room names....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
604.3.2 Overlap
around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor...
-
11B-407.4.1 Car dimensions
Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with Section 11B-407.4.1, existing elevator car configurations that provide a clear floor...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
11B-703.1.1.2 Inspection
11B-703.1.1.2 Inspection. Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
4.3.4 Tent Pad or Platform Surface
Tent pads and platforms shall have a surface that is firm and stable and is designed to allow use of tent stakes and other tent securing devices. Exception. Where a condition for...
-
1.1.6
1.1.6 Accessible surfaces should be as smooth as possible. This includes localized variations in slope as well as bumpiness created by small, individual units such as bricks,...