- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
Lavatories Adjacent to Partitions
Although we often times see accessories such as hand dryers or paper towel dispensers installed on the wall adjacent to the lavatory, the accessories cannot encroach into the clear floor...
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
- SDC S6000 Spectra Exit Devices
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
4.35.4 Bench
The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....
-
Section H: Lifts
(§410.1) H3 Is there 30" by 48" of clear floor space within the lift?...
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant names,...
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. [S.H. Visual character style not addressed...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
216.1 General
Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas, occupant...
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
216.1 General
216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas,...
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
4.1.2(7) Building Signage