11B-1009.4 Transfer walls
-
11B-1009.4 Transfer walls
Transfer walls shall comply with Section 11B-1009.4....
-
11B-1009.5 Transfer systems
Transfer systems shall comply with Section 11B-1009.5....
-
11B-1009.5 Transfer systems
Transfer systems shall comply with Section 11B-1009.5....
-
11B-1009.4 Transfer walls
Transfer walls shall comply with Section 11B-1009.4....
-
Additional Technical Criteria Considered for Transfer Supports
As discussed below, the Access Board is considering whether additional technical criteria would be appropriate for transfer supports....
-
How To: Transfer from Floor to Chair Video
Requires the Registered User plan or above. Login!
-
5.2.1.2 Transfer Surface Depth Recommendation for M301
5.2.1.2 Transfer Surface Depth Recommendation for M301 The Committee recommends a minimum transfer surface depth of 17 inches for all M301 except imaging equipment....
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided....
-
11B-1008.3.1.4 Transfer supports
At least one means of support for transferring shall be provided....
-
Transfer Surface
Part of diagnostic equipment onto which patients who use mobility devices or aids transfer when moving onto and off of the equipment....
-
Transfer Surface
Part of diagnostic equipment onto which patients who use mobility devices or aids transfer when moving onto and off of the equipment....
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
Transfer Protocols
For each transfer, participants were asked to position themselves next to the platform as they normally would to prepare for a transfer....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
11B-1008.3.1 Transfer platforms
Transfer platforms shall be provided where transfer is intended from wheelchairs or other mobility aids. Transfer platforms shall comply with Section 11B-1008.3.1....
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report May 31, 2013 The Subcommittee’s technical recommendations for the stretchers...
-
11B-1008.3.2.4 Contrasting stripe
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step....
-
11B-1008.3.2.4 Contrasting stripe
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step....
-
4.3.2 Transfer Surfaces and Imaging Equipment Functions
These components may, with current designs, impede lowering the table to accessible minimum heights....
-
a. Transfer Surface Adjustability
The Access Board sought public comment in the MDE NPRM preamble on whether the final standards should require the height of the transfer surface to be adjustable from 17 inches minimum to...
-
§ 36.302(f)(6) Ticket transfer
(6) Ticket transfer....
-
M301.2.3 Transfer Sides
The configuration of stretchers will not allow for unobstructed access to a transfer surface located at either the foot end or head....