Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
Search Results "Stair Signage"
Commonly Searched Documents
-
11B-703.5.3 Style
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
Stairs
Result: People who use crutches or a cane or who have limited balance may fall at the top or bottom of the stairs because they have no railing to hold onto as they make the transition...
-
Continuity: ADA Standard Section 505.3
Section 505.3 covers the current ADA Standards for the continuity of handrails.
-
Wet Conditions: ADA Standard Section 504.7
Section 504.7 covers the current ADA Standards for wet conditions at stairways.
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
- Access Board: Tactile Sign Height
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Are stairs that are not part of means of egress required to comply with the Standards?
No, interior or exterior stairs that are not part of a required means of egress do not have to meet the Standards....
-
1.2.8 Exterior stairs, cast - in - place
1.2.8 Exterior stairs, cast - in - place....
- American Stair Corp. FasTrack Treads & Landings
- Takeform Fusion Signage Miscellaneous Room Identification Type E.2
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
703.5.5 Character Height
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
703.5.5 Character Height
703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
A4.30.5 Finish and Contrast
An eggshell finish (11 to 19 degree gloss on 60 degree glossimeter) is recommended. Research indicates that signs are more legible for persons with low vision when characters...
-
4.30.5* Finish and Contrast
4.30.5* Finish and Contrast. The characters and background of signs shall be eggshell, matte, or other non-glare finish. Characters and symbols shall contrast with their background...
-
4.30.3* COLOR CONTRAST
Characters and symbols shall contrast with their background - either light characters on a dark background or dark characters on a light background.
-
11B-703.5.5 Character height
11B-703.5.5 Character height. Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
Non-Tactile Signage
Non-Tactile Signage The legibility of printed characters is a function of the viewing distance, character height and proportion, font, and the color contrast between character and background...
- Innerface Parallel Interior Signage
-
SIGNAGE
SIGNAGE. [DSA-AC] Displayed verbal, symbolic, tactile, and/or pictorial information....