The National Technology Transfer and Advancement Act of 1995 (NTTAA) directs that, as a general matter, all Federal agencies and departments shall use technical standards that are developed...
Search Results "NFPA: National Fire Protection Association"
-
National Technology Transfer and Advancement Act of 1995
-
National Technology Transfer and Advancement Act of 1995
The National Technology Transfer and Advancement Act of 1995 (NTTAA) directs that as a general matter, all Federal agencies and departments shall use technical standards that are developed...
-
[F] 907.4.2 Manual fire alarm boxes
...
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-405.9.2 Curb or barrier
ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted by 2010 ADAS....
-
11B-405.9.2 Curb or barrier
[Safe Harbor 11B-405.9.2] ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface...
-
11B-405.9.1 Reserved
11B-405.9.1 Reserved. [2010 ADAS] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond...
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face...
-
F215 Fire Alarm Systems
[See subsections ...]
-
215 Fire Alarm Systems
[See subsections ...]
-
PARTNERING ASSOCIATIONS OFFERING DISCOUNTED OR COMPLIMENTARY SUBSCRIPTIONS
[See subsections ...]
-
907.2.8.1 Fire detection system
single-station smoke alarms required by Section 907.2.10 are connected to the emergency electrical system and are annunciated by guestroom at a constantly attended location from which the fire...
-
4.1.7(2)(a)(i)
Section 106 of the National Historic Preservation Act (16 U.S.C. 470 f) requires that a Federal agency with jurisdiction over a Federal, federally assisted, or federally licensed undertaking...
-
1009.12 Alarms/emergency warning systems/two-way communication systems
Emergency warning systems provided as part of the fire alarm system and two-way communication systems required by Chapter 10 shall be designed and installed in accordance with NFPA 72 as...
-
1009.12 Alarms/emergency warning systems/accessibility
Emergency warning systems provided as part of the fire-alarm system and two-way communication systems required by Chapter 10 shall be designed and installed in accordance with NFPA 72 as...
-
FAQ: What does "powered by Evan Terry Associates" mean?
Corada was developed and is maintained by Evan Terry Associates, for the purpose of helping people to identify, to understand, and to meet their obligations under the ADA and other access...
-
Are fire extinguishers required to comply with the ADA Standards?
In general, elements that are not fixed or built in, including fire extinguishers, are not required to comply with the ADA Standards....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see "Referenced Standards"...
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 (incorporated by reference, see "Referenced Standards"...
-
Curb or Barrier: ADA Standard Section 1005.3.1
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.