(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
Search Results "Expected Maximum Flight Duration"
-
4.1.6(3)(d)(i)
- Access Board: Unobstructed Side Reach
-
Forward Reach [4.2.5]
forward reach over an obstruction is limited by how far a person using a wheelchair can pull up below it, the depth of reach cannot exceed the amount of usable clear floor space (25 inches maximum...
-
Exemptions for Entire Trail or Beach Access Route
The proposed rule would have exempted an entire trail from complying with the technical requirements for trails when: The combination of running slope and cross slope...
-
202.5 Alterations to Qualified Historic Buildings and Facilities
facilities that are eligible for listing in the National Register of Historic Places or are designated as a Recorded Texas Historic Landmark or State Archeological Landmark shall comply to the maximum...
-
4.25.3 Height
Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach....
-
4.1.6(2)
the requirements of 4.1.6(1), an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum...
-
Side reach (Section-by-Section Analysis)
The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3.1 reduce that maximum height to 48 inches....
-
Side reach (Section-by-Section Analysis)
The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3 reduce that maximum height to 48 inches....
-
202.5 Alterations to Qualified Historic Buildings and Facilities
Alterations to a qualified historic building or facility shall comply with 202.3 and 202.4 to the maximum extent feasible....
-
5. Site Constraints, Technical Infeasibility, and Unusually Expensive Remediation
Work on difficult sites may be postponed if there is an alternative accessible route within no more than 200 feet, to the maximum extent feasible. ...
-
1017.1 General
Trails shall comply with 1017. EXCEPTIONS: 1. When an entity determines that a condition in 1019 does not permit full compliance with a specific provision in 1017 on a portion of...
-
Additions [4.1.5]
Each addition to an existing building is regarded as an alteration subject to ADAAG alterations requirements (including triggering of path of travel obligations, if applicable). To...
-
4.1.6(3)(c)(ii)
(ii) Where existing shaft configuration or technical infeasibility prohibits strict compliance with 4.10.9, the minimum car plan dimensions may be reduced by the minimum amount...
-
Alterations/ Historic Preservation
Steeper slopes are allowed for short ramps where a 1:12 slope is not technically feasible. Scope Max Rise Max Slope altered facilities (including...
-
Alterations: Alternate Stalls
Alterations: Alternate Stalls An alternate stall may be substituted for the standard stall only in alterations where full compliance with requirements for a wheelchair accessible...
-
1017.1 General
Trails shall comply with 1017. EXCEPTIONS: 1. When an entity determines that a condition in 1019 does not permit full compliance with a specific provision in 1017 on a portion of...
-
Alterations
In situations where strict compliance with the Standards is technically infeasible, the entity must comply to the maximum extent feasible....
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
Slope and Rise [4.8.2]
A maximum slope of 1:12 is specified although ADAAG calls for the "least possible" slope to encourage more gradual slopes which better serve children and people with limited stamina or upper...
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
1019.1 General
Exceptions to specific provisions in 1011, 1013, 1014, 1015, 1016, 1017, and 1018 shall be permitted when an entity determines that any of the following conditions does not permit...