As discussed in Section IV.B.1.a. (Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a...
Search Results "Examination"
Commonly Searched Documents
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301) The Committee recommends a transfer surface size on imaging equipment be a minimum of 28 inches long by...
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum. The transfer surface should be located such...
-
M301.2.2 Transfer Surface Size
M301.2.2 Transfer Surface Size Subcommittee Recommendation: (Also agreed to by the full committee). A. The minimum size of the transfer surface is 28 inches wide minimum and 21...
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum...
-
Examination Chair
Examination chairs typically have back support and may recline to properly position the patient during examination. Such chairs may also have footrests or stirrups....
-
Features of Accessible Exam Tables
Features of Accessible Exam Tables 1. Removable/adjustable support rails with continuous gripping surfaces 2. 30” X 48” minimum clear floor space adjacent to exam table and...
-
5.7.1 Lift Compatibility Clearance in Base for M301
to be effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise the patient onto and off examination...
-
5.3.2 Transfer Sides Recommendations for M301
., foot of an examination table)....
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical...
-
Sections 35.108(d)(2) and 36.105(d)(2)—Predictable Assessments
Sections 35.108(d)(2) and 36.105(d)(2)—Predictable Assessments In the NPRM, proposed §§ 35.108(d)(2) and 36.105(d)(2) set forth examples of impairments that should easily be found...
-
How to Measure Transfer Surface Height
Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
Medical Examinations
Medical Examinations An employer may only make medical examinations or inquiries of an employee regarding disability if such examinations are job-related and consistent with business...
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed a clearance in the base of 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination...
-
11B-805.4 Examination, diagnostic and treatment rooms
Examination, diagnostic and treatment rooms shall comply with Section 11B-805.4....
-
M301.3.1 Transfer Supports
M301.3.1 Transfer Supports Subcommittee Recommendation: (Also agreed to by the full committee.) A) For transfer depths less than or equal to 24 inches a transfer support will...
-
5.3.2.2 Transfer Sides for Imaging Equipment
5.3.2.2 Transfer Sides for Imaging Equipment. The transfer surface should be provided on at least one long side of the table.
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in...
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface...
-
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface for Imaging Equipment. Supports (transfer or positioning) should be located 1 ½ inches maximum from the transfer surface. The...
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
5.2.1.1 Transfer Surface Width Recommendations for M301
As part of the deliberations, Committee members examined tables and chairs from various manufacturers during its meetings....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. EXCEPTION: Where fixed overhead patient...