Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 100 mm (4 in) minimum and 160 mm (6.25 in) maximum, and a cross-section dimension of 57 mm...
Search Results "Gripping Surface"
Commonly Searched Documents
-
R409.7.2 Non-Circular Cross Sections
-
R409.7 Cross Section
Handrail gripping surfaces shall have a cross section complying with R409.7.1 or R409.7.2....
- Boost Your Business - Chapter 6 - Doors
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
Openings in Outdoor Recreation Access Route Surfaces
Openings are gaps in the surface of an outdoor recreation access route. Gaps include spaces between the planks on a boardwalk or in a drainage grate....
-
Play Areas
Word Fillable Form (0.4MB) Word Non-Fillable Form (0.3MB) PDF Non-Fillable Form (0.3MB)
-
25. Please indicate the date (year) of trail surface installation
Please indicate the date (year) of trail surface installation:...
-
Why a smooth surface door or kickplate is important
Remember that the latch that hits the push rim is nicking the surface your fingers have to grasp thousands of times a day for years....
-
Attachment J
Provide handrails that are between 1¼ inches and 1½ inches in diameter with a continuous gripping surface along both sides of the ramp, extending at least 12 inches beyond the top and bottom...
-
4.17.6 Grab Bars
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
Transfer Height
Transfer Height The height of the transfer device must be between 14 and 24 inches above the load and unload area surface....
-
What is a good un-official "working" definition of "work surface"?
11B-805.7 goes on to list numerous items that would/could be included in the broad verbiage of "Built-in cabinets, counters and work surfaces"....
-
What values are recommended for ground and floor surfaces along an accessible route?
What values are recommended for ground and floor surfaces along an accessible route?...
-
surface mounted toilet paper dispensers
Surface mounted dispensers are now being used for design and construction convenience, and they appear to pose an unnecessary hazard of injury due to the amount they project from the wall...
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
The proposed provision requires standing supports be provided on each side of the standing surface....
-
Transfer Devices for Use with Amusement Rides: ADA Standard Section 1002.6
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches 430 to 485 mm) above the load and unload surface....
-
11B-1002.6 Transfer devices for use with amusement rides
Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
Durability and Maintenance of Detectable Warning Surfaces (Section-by-Section Analysis)
Durability and Maintenance of Detectable Warning Surfaces (Section-by-Section Analysis) Transportation officials who commented on the 2002 draft guidelines expressed concern about the...
- Mockett DH3/BB Square Door Handle Installation Video
-
FACTS APPLICABLE TO ALL CLAIMS
FACTS APPLICABLE TO ALL CLAIMS 24. As a result of Defendant's policies and practices with regard to curb ramps in the City's pedestrian right of way, people with mobility...
-
R409.10 Handrail Extensions
Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs and stair flights in accordance with R409.10....
-
M305.2.7 Clearance (Section-by-Section Analysis)
Specifically, the Access Board sought input from the public in question 22, on whether transfer supports on diagnostic equipment could provide 1½ inches minimum clearance around the gripping...