Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
Search Results "Gripping Surface"
Commonly Searched Documents
-
Amusement Ride Seats Designed for Transfer: ADA Standard Section 1002.5
-
11B-1002.5 Amusement ride seats designed for transfer
Where possible, designers are encouraged to locate the ride seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface....
-
M301.3 Transfer Supports
Section may be discontinuous (see Rationale) along the length of the Gripping Surface not exceeding 20% of the length of the gripping surface....
-
505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1½ inches (38 mm) minimum. Figure 505.5 Handrail Clearance...
-
T303.3 Cross Section
Gripping surfaces shall have a cross section complying with T303.3....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
What surface characteristics are required of an accessible route?
What surface characteristics are required of an accessible route?...
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
- AJW Architectural Products UG3-Railing UG3X-Y108 108" Concealed Snap Flange, 1.5" Diameter, Peened Grip - Configuration Y
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Grab Bars: ADA Standard Section 1009.4.5
The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
R305 Detectable Warning Surfaces (Section-by-Section Analysis)
R305 Detectable Warning Surfaces (Section-by-Section Analysis) Detectable warning surfaces consist of truncated domes aligned in a square or radial grid pattern....
- #CrappyCurb
-
5.3 Transfer Sides
5.3 Transfer Sides.
-
5.3 Transfer Sides Recommendations
5.3 Transfer Sides Recommendations
-
Curb Ramp Requirements [§406]
Curb Ramp Requirements [§406]