Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with Section 11B-1008.2.6. Advisory 11B-1008.2.6 Ground surfaces....
Search Results "Floor Designation"
-
11B-1008.2.6 Ground surfaces
- W3C: Responsive Web Design
- The RERC on Workplace Accommodations
-
302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. EXCEPTIONS: 1....
-
302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. EXCEPTIONS: 1....
- Access Board: Tactile Sign Braille Requirements
-
302.1 General
Floor and ground surfaces shall be stable, firm, and slip resistant and shall comply with 302. EXCEPTIONS: 1....
-
703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1011.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2...
-
F216.4.1 Exit Doors
Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory F216.4.1 Exit Doors. An exit...
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. [S.H. Visual character style not addressed...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
703.1 General
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
216.4.1 Exit Doors
216.4.1 Exit Doors. Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5. Advisory 216.4.1...
-
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4]
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4] Raised characters are required to have simple, preferably no, serif. Fancy serif styles make tactile reading...
-
Accessibility Guidebook for Outdoor Recreation and Trails
August 2012 2300 Recreation 1223-2806P-MTDC Janet Zeller, National Accessibility Program Manager Ruth Doyle, Cibola National Forest Recreation,...
-
F216.1 General
Signs shall be provided in accordance with F216 and shall comply with 703.
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2...
-
11B-703.1 General
11B-703.1 General. Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two...
-
11B-703.5.3 Style
11B-703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...