Audible indicators shall comply with Section 11B-407.4.8.2.
Search Results "Private Residence Elevator"
-
11B-407.4.8.2 Audible indicators
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
407.4.8.2 Audible Indicators
407.4.8.2 Audible Indicators. Audible indicators shall comply with 407.4.8.2.
-
407.4.8.2 Audible Indicators
Audible indicators shall comply with 407.4.8.2.
-
407.4.3 Platform to Hoistway Clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1 1/4 inch (32 mm) maximum.
-
407.4.3 Platform to Hoistway Clearance
407.4.3 Platform to Hoistway Clearance. The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
What is the difference between Title II and Title III of the ADA?
Title III applies to the private sector such as businesses and non-profit organizations....
-
5f.
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Stds 4.10.13]...
-
11B-206.2.3 Multi-story buildings and facilities
The following types of privately funded multistory buildings do not require a ramp or elevator above and below the first floor: 1.1 Multi-storied office buildings (other than the...
-
e-vii
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
A4.10.13 Car Position Indicators
A special button may be provided that would activate the audible signal within the given elevator only for the desired trip, rather than maintaining the audible signal in constant operation...
-
A4.10.13 CAR POSITION INDICATORS
A special button may be provided that would activate the audible signal within the given elevator only for the desired trip, rather than maintaining the audible signal in constant operation...
-
Accessible Route to Play Components
When elevated play components are provided, an accessible route must connect at least fifty percent (50%) of the elevated play components....
-
407.2.1.3 Clear Floor or Ground Space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
11B-703.7.2.1 International Symbol of Accessibility
On the accessibility function button on hall call consoles in a destination-oriented elevator system the International Symbol of Accessibility shall be a white symbol on a black background...
-
11B-703.7.2.1 International Symbol of Accessibility
On the accessibility function button on hall call consoles in a destination-oriented elevator system the International Symbol of Accessibility shall be a white symbol on a black background...
-
Machinery Spaces (§203.5)
Machinery Spaces (§203.5) Spaces used only by service personnel for maintenance, repair, or occasional monitoring of equipment Examples: elevator pits/ penthouses, mechanical/...
-
Emergency Communication [§407.4.9]
Emergency Communication [§407.4.9] The ASME A17.1 code requires a two-way means of emergency communication in elevator cars....