Search Results "Hinge Side Clearance"
-
Transfer Entry
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
4.13.11(2)(a)
(a) exterior hinged doors: (Reserved)....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
4.13.11(2)(b)
(b) interior hinged doors: 5 lbf (22.2N)...
-
2.2.6 Door Use
clearance > 1525 mm > 1525 mm > 1525 mm Pull side clearance > 1525 mm > 1525 mm > 1525 mm Push side latch side...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
11B-404.3 Automatic and power-assisted doors and gates
An automatic door may be used as equivalent facilitation when it is technically infeasible to provide sufficient strike-side clearance for code compliance, but a power-assisted door may...
-
1010.1.7 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
-
MEASUREMENT TECHNIQUE
measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth is measured between the perineal cutout and the hinge...
-
4.13.11* DOOR OPENING FORCE
(a) exterior hinged doors: (Reserved)....
-
1118B.6
SECTION 1118B - SPACE ALLOWANCE AND REACH RANGES 1118B.6 Side reach. ...
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
Clear Deck Space
This will allow persons using a wheelchair to turn around and access the wall, depending on the side they can best use to transfer....
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
-
11B-809.10.5.4 Bathtub enclosures
Hinged doors shall open outward. Glazing used in doors and panels of bathtub enclosures shall be fully tempered, laminated safety glass or approved plastic....
- Accessible Parking Video Fact Sheet
-
Water Closet Clear Floor Space in Toilet Compartments
Other criteria for toilet rooms, including turning space, maneuvering space at doors, and clearances at other fixtures, typically results in additional clearance at water closets not in...