Lengthen the ramp, or rebuild it to include switchbacks High countertop in check-in area makes it difficult to see staff and sign in Place sign check-in equipment on a side...
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
4.2 Physical Accessibility Barriers and Solutions
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Handrails
Handrails Handrails are required on both sides of ramps connecting elevated play components....
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
3. Doors
Doors with 32 inches of clear opening width (when a sliding door is fully opened or a hinged door is open 90 degrees). Clear floor space is required in front of the door....
- Corbin Russwin Inc. DC46900 Series Safeguard Door Closers
-
803 Dressing, Fitting, and Locker Rooms
In the proposed rule, an exception to this provision noted that a portion of this space (6 inches maximum) could extend under partitions or openings without doors that provide toe clearance...
- AJW Architectural Products U592 1.6 Gallon Sanitary Napkin Disposal w/ Keyed Access Panel & Mounted Shelf - Surface Mounted
-
Library
Offset pivot hinge on door to library Large print books in the library Handrails at two height Evaporative cooler to save the energy used by air conditioners...
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
- Eliason Corporation SCP-8 High Pressure Laminate Traffic Door
-
804 Kitchens and Kitchenettes
Clearances for pass through kitchens address counters, appliances, or cabinets on two opposing sides....
- Figure 604.3.1 Size of Clearance at Water Closets – Drawing from the U.S. Access Board
-
Example of a Single-User Bathroom (with Roll-in Shower)
Where clear floor space at a lavatory is obstructed on both sides more than 2 feet, a clearance at least 36 inches wide is required....
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
804.6.2 Operable Parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3....
-
804.6.2 Operable Parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: Interior hinged doors and gates: 5 pounds (22.2 N) maximum....