[2010 ADAS] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches deep with a wall-hung water closet or 65 inches deep with a floor-mounted...
Search Results "Water Depth"
Commonly Searched Documents
-
11B-604.8.1.4 Toe clearance
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
open-air structures, or buildings equipped with "supervised automated sprinkler systems, “which are systems with built-in signals used to monitor system features (the opening and closing of water...
-
1011.3 Operable Parts
Exception 1 requires fire rings, grills, fireplaces, wood stoves, water hydrants, and water utility hook-ups to comply with the technical requirements for operation in 309.4 of the Architectural...
-
1134A.2 Number of complying bathrooms
Water closets shall comply with Section 1134A.7. 5. Lavatories, vanities, mirrors and towel fixtures shall comply with 1134A.8. 6. ...
-
1134A.2 Number of complying bathrooms
Water closets shall comply with Section 1134A.7. 5. Lavatories, vanities, mirrors and towel fixtures shall comply with 1134A.8. 6....
- American Standard Colony PRO Two-Handle Kitchen Faucet with High-Arc Swivel Spout 7074.550
- American Standard Colony PRO Two-Handle Kitchen Faucet with Low-Arc Swivel Spout 7074.500
- Hager Companies 36" Low Profile Actuator 2-659-0179 - Hard Wired
- Hager Companies 36" Low Profile Actuator 2-659-0178 - Wireless
- Bobrick Recessed Medicine Cabinet B-397
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8HPS
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8
-
Curb Ramps at Marked Crossings and Vehicular Lanes
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
307 Protruding Objects
., higher than 27 inches from the floor) and below the standard head room clearance (80 inches), are limited to a 4 inch depth....
-
Summary
Summary The following report provides a brief analysis of four anthropometric dimensions which were considered relevant to the width and depth dimensions of a seating surface for wheeled...
-
711.3.2 Membrane penetrations
By a horizontal distance of not less than the depth of the wall cavity where the wall cavity is filled with cellulose loose-fill or mineral fiber insulation; 1.3....
-
Typical Issues
Access aisle depth is at least 5 feet. 2. Access aisle length is at least 20 feet. 3....
-
Clearance in Base (M301.4.1 and M302.4.1)
Where the width of the examination surface is less than 36 inches, the clearance depth would be required to extend the full width of the equipment....
-
Lateral grab bar use
Table 12 summarizes the average clear space required for our subjects to position their WMD to perform a transfer in each protocol in terms of width, depth, and angle of approach (Figure...
-
Stabilizer
Stabilizer arrives pre-mixed with ¼ inch minus aggregate and is applied at a 3-inch depth on top of the base....
- Pressalit Care Adult changing table 3000, electrically height adjustable
-
Employee Work Areas: ADA Standard Section 206.2.8
Section 206.2.8 covers scoping requirements in the most current ADA Standards for accessible routes in employee work areas.
-
Urinals
Some comments questioned the degree to which men with disabilities use or prefer urinals over water closets....
-
608 Shower Compartments
alternate roll-in showers (608.2.3) shower seats (608.4) the location and operation of controls, faucets, and spray units (608.5) shower spray units and water...