The hand-held shower spray unit shall have at least one fixed position located 15 inches minimum (380 mm) and 48 inches (1220 mm) maximum above the ground....
Search Results "Horizontal Position"
-
1011.7 Outdoor Rinsing Showers
-
904.4.1 Parallel Approach
A clear floor or ground space complying with 305 shall be positioned for a parallel approach adjacent to the 36 inch (915 mm) minimum length of counter....
-
804.3.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
2.1.3 Receivers
All the person has to do is enter the field and switch the hearing aids to the telecoil position....
-
1011.7 Outdoor Rinsing Showers
The hand-held shower spray unit shall have at least one fixed position located 15 inches minimum (380 mm) and 48 inches (1220 mm) maximum above the ground....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
Q2.) What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
In lawsuits that the Department of Justice has filed, DOJ has taken the position that tolerances cannot be predefined but must always be considered on a case-by-case basis considering the...
-
SCOTT JOHNSON v. STARBUCKS CORPORATION - AMICUS BRIEF
One of those claims posits that Defendants have violated Section 904.4.1 of the 2010 ADA Standards for Accessible Design (2010 Standards) because they have failed to provide 36 inches of...
-
2004 ADA and ABA Accessibility Guidelines
proposed standards are based on the 2004 ADA and ABA Accessibility Guidelines: • Height of transfer surfaces on diagnostic equipment used by patients in a supine, prone, or side-lying position...
-
11B-604.8.1.1 Size
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet....
-
Transfer Protocols
For each transfer, participants were asked to position themselves next to the platform as they normally would to prepare for a transfer....
- Endorphin 325 Functional Wall Pulley
- Sizewise SW Low Boy
- GE Senographe Essential Digital Mammography System
- Endorphin 355 Series e4 Resistance System
- Norton Surface Mounted 7900 Series Overhead Door Closer
- Landscape Forms Inc. Max Transportation Stop Shelters
- Norton Surface Mounted 5900 Series Low Energy Door Operator
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
Front grab bar protocol
The horizontal distance between the center of the grab bar and the mid-center, front edge of the platform was 13.5”. ...
-
Sight Lines
Sight Lines Both the horizontal and vertical viewing angles must be considered in the design of assembly areas....