For side-opening ovens, the door latch side shall be next to the open counter space, and there shall be a pull-out shelf under the oven extending the full width of the oven and pulling out...
Search Results "Side Transfer"
Commonly Searched Documents
-
4.34.6.7* OVENS
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-231.4.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
Court Sports
Accessible routes must comply with all ADAAG requirements, such as width and changes in level or surface, and must directly connect both sides of the court....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-231.4.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
11B-232.5.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
4. Toilet seat height
Toilet seat height: The toilet seat needs to be from 17 to 19 inches above the floor to permit transfers to and from wheelchairs....
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
§8.10(c)(2)
(2) Hiring, upgrading, promotion, award of tenure, demotion, transfer, layoff, termination, right of return from layoff, injury or illness, and rehiring;...
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
- PEMKO 5 9/16" Thermal Barrier Threshold No. 273x292-FGPK
- Cybex Total Access Recumbent Bike
-
F216.12 Amusement Rides
Amusement rides designed primarily for children, amusement rides that are controlled or operated by the rider, and amusement rides without seats, are not required to provide wheelchair spaces, transfer...
-
216.12 Amusement Rides
Amusement rides designed primarily for children, amusement rides that are controlled or operated by the rider, and amusement rides without seats, are not required to provide wheelchair spaces, transfer...
-
903.4 Back Support
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
- Spectrum Aquatics Traveler II XRC500 Pool Lift
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....