... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
Search Results "Lavatory Height"
Commonly Searched Documents
-
1011.5.2 Riser height and tread depth
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1134A.7 Water closets
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet...
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Because the picture was taken directly from the ANSI A117.1 1986 standard, the diagram also shows the height of the obstruction, which, in this picture, is a countertop....
-
4.34.4 CONSUMER INFORMATION
the owner or occupant of a dwelling, the following consumer information shall be provided in each adaptable dwelling unit available for occupancy: (1) Notification of the alternate heights...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet seat height complying with Section 11B-809.10.7.4. 7. Electrical receptacles, switches and controls complying with Section 11B-809.12. 8....
-
Can parking signage height be considered a "safe harbor"?
No specific height dimension given. For an older property with parking signs mounted at, say 45" inches to the bottom, are these protected by the safe harbor rule? ...
-
Toilet and Bathing Rooms: ADA Standard Section 805.4
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
1134A.5 Bathtubs
The area under a lavatory, located at the control end of the tub, may be included in the clear floor space provided the lavatory is 19 inches (483 mm) maximum deep, and the knee and toe...
- Boost Your Business - Chapter 10 - Restroom Fixtures
-
§382.63(b)
(b) With respect to aircraft with only one aisle in which lavatories are provided, you may, but are not required to, provide an accessible lavatory....
- Figure 302.2 Carpet Pile Height – Drawing from the U.S. Access Board
- Figure 1009.4.2 Transfer Wall Height – Drawing from the U.S. Access Board
-
Pressalit Care PLUS Support Arm Height Adjustable Swing Grab Bar
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ADA & Level Boarding Guidance - Platform Height
49 CFR §§37.41-43; 37.9(a), (d); 49 CFR Part 37, App. A (810.5.3) DECEMBER 14, 2011
-
11B-809.10.7.3 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
Clear Floor Space [4.20.2]
ADAAG allows a lavatory on the same plumbing wall to overlap the clear floor space at the tub because knee and toe clearance is available below an accessible lavatory....
-
§382.63(a)
(a) As a carrier, you must ensure that aircraft with more than one aisle in which lavatories are provided shall include at least one accessible lavatory....
-
11B-806.2.4 Toilet and bathing facilities
No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of Sections 11B-603 through 11B-610....
-
Single-User Toilet Rooms: Split Plumbing
Single-User Toilet Rooms: Split Plumbing Water closets and lavatories can be located on opposing walls....