Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
Search Results "Lavatory Height"
-
11B-811.3 Height
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
Exposed Pipes and Surfaces: ADA Standard Section 606.5
Section 606.5 covers the current ADA Standards for exposed pipes and surfaces under lavatories and sinks.
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
11B-606.5 Exposed pipes and surfaces
Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact....
-
M305.1 General
Supports shall comply with M305.
-
M305.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF...
-
M305.1 General
Supports shall comply with M305, as applicable.
-
11B-213.3.1 Toilet compartments
A toilet compartment may also contain a lavatory....
-
11B-213.3.1 Toilet compartments
A toilet compartment may also contain a lavatory....
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
11B-809.10.7.3 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
11B-809.10.7.3 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To see...
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Height....
-
F213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
-
213.3.1 Toilet Compartments
A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing....
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100