3.3.9 Toe Clearance Depth, minimum Toe clearance depths for the standards range from 150 mm (6 in.) in the U.S. to 230 mm (9 in.) in Canada (Figure 3‒9)....
Search Results "Referenced Standard"
-
3.3.9 Toe Clearance Depth, minimum
-
15(d)
subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of accessible rooms with roll-in showers as set forth in ADA Standards...
-
M101.1 Purpose
The standards contain technical criteria for medical diagnostic equipment that is accessible to and usable by patients with disabilities....
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
Single User Restroom Accessibility
As a CASp or Accessibility consultant, you probably find yourself navigating between the requirements of the ADA Standards, the California Building Code, and legislative requirements that...
-
Ambulatory Accessible Toilet Compartments
Section 213.3.1 of the 2010 Standards requires multi-user men’s toilet rooms, where the total of toilet compartments and urinals is six or more, to contain at least one ambulatory accessible...
-
Toilet Stalls [4.17]
Toilet Stalls [4.17] The standard stall in section 4.17 is wheelchair accessible....
-
§40.6 Records.
agency's file on each contract, grant, or loan involving the design, construction, or alteration of a residential structure shall include appropriate documentation indicating: (a) That the standards...
-
§ 35.150(b)(2)(i) Safe harbor
have not been altered in existing facilities on or after March 15, 2012 and that comply with the corresponding technical and scoping specifications for those elements in either the 1991 Standards...
-
General: ADA Standard Section 221.1
Section 221.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for assembly areas.
-
E202.7 Best Meets
Where ICT conforming to one or more requirements in the Revised 508 Standards is not commercially available, the agency shall procure the ICT that best meets the Revised 508 Standards consistent...
-
M101.1 Purpose
The proposed standards contain technical criteria for medical diagnostic equipment that is accessible to and usable by patients with disabilities....
-
11B-202.3.1 Prohibited reduction in access
(c) If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the...
-
Multiple Single-User Toilet Rooms
Where multiple single-user toilet rooms are clustered in a single location, fifty percent (50%), rather than the one hundred percent (100%) required by the 1991 Standards, are required to...
-
5.2.2.1 Transfer Surface Width Recommendations for M302
recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily used by patients in a seated position as described in its proposed standard...
-
B.3.iv - Who makes the determination that a product meets equivalent facilitation?
The vendor may assert that its product meets or exceeds the level of accessibility required by a particular standard through equivalent facilitation....
-
24.1 Q. What types of grab bars should the reinforcement be designed to accommodate and what types may be used if the builder elects to install grab bars in some units at the time of construction?
In determining what is an appropriate grab bar, builders are encouraged to look to the 1986 ANSI A117.1 standard, the standard cited in the Fair Housing Act....
-
§ 36.304(d)(2)(iii)
., elements for which there are neither technical nor scoping specifications in the 1991 Standards), and therefore those elements must be modified to the extent readily achievable to comply...